Code No. U1005 Corner/Back SNS.ECU CAN timeout



caution
  • If diagnosis code No. U1005 is set to the ETACS-ECU, always diagnose the CAN bus line.
  • Before replacing the ECU, ensure that the power supply circuit, the earth circuit and the communication circuit are normal.
  • When the ETACS-ECU of vehicles without KOS is replaced, the encrypted code of the ignition key needs to be registered to the ETACS-ECU. (If the encrypted code is not registered, the engine cannot be started. Register the encrypted code as described in Immobilizer System - How to Register Key ID .)

DIAGNOSTIC FUNCTION




JUDGEMENT CRITERIA




  • No abnormality is present to the network.
  • Ignition switch is in the ON position.
  • No abnormality is present to the power supply fuse (IOD fuse), or the odometer value is at 80.5 km or more.
  • ETACS-ECU system voltage is at 10-16 V.

PROBABLE CAUSES



  • Malfunction of the corner sensor/back sensor-ECU
  • Malfunction of the ETACS-ECU
  • Malfunction of the CAN bus

DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III CAN bus diagnostics



Q. Is the check result normal?





STEP 2. Check the M.U.T.-III Diagnosis code for other systems



Q. Is the diagnosis code set?





STEP 3. Check whether the diagnosis code is reset.



(1)Erase the diagnosis code.
(2)Turn the ignition switch from the LOCK (OFF) position to the ON position.
(3)Check if the diagnosis code is set.

Q. Is the diagnosis code set?





STEP 4. Check whether the diagnosis code is reset.



(1)Erase the diagnosis code.
(2)Turn the ignition switch from the LOCK (OFF) position to the ON position.
(3)Check if the diagnosis code is set.

Q. Is the diagnosis code set?